钢格板安装需要注意些什么?
1、钢格板的焊接安装:首先把钢格板焊接在支承梁上,以形成坚固的永久性连接。焊接要求:
1. Welding and Installation of Steel Grid Plate: Firstly, the steel grid plate is welded on the supporting beam to form a strong permanent connection. Welding requirements:
A、焊接前必须清除干净支承钢梁和钢格板表面上的锌层、油漆、铁锈、油污和水等。
A. Before welding, the zinc layer, paint, rust, oil and water on the surface of supporting steel beam and grille must be removed.
B、如果在焊接采用分段焊,焊缝长度不小于25mm。焊角高度不小于5mm,焊于钢格板承载扁钢一侧,焊缝数量参见下,焊接后,去除焊渣和飞溅,手工涂两道富锌漆。
B, if the welding is segmented, the weld length should not be less than 25mm. Welding angle height is not less than 5 mm, welded on the side of steel grille bearing flat steel, weld number see below, after welding, remove welding slag and spatter, hand-painted two zinc-rich paint.
焊接安装的弊端在于,焊接处容易生锈。
The disadvantage of welding installation is that the welds are easy to rust.
2、钢格板的安装夹数量方法;将钢格板用安装夹紧固在支承粱上,原则上每块钢格板(约1平方米)不少于四套安装夹,安装在钢格板的四个角。
2. Installation clamp quantity method of steel grille plate; fasten steel grille plate on supporting beam with installation clamp, in principle, each steel grille plate (about 1 square meter) not less than four sets of installation clamp, installed in the four corners of steel grille plate.
但如果钢格板较长,且板中间有支承梁的情况下,安装夹可按实际情况配置。
But if the steel grille is long and there is a supporting beam in the middle of the plate, the clamp can be configured according to the actual situation.
安装夹各零件包括:(上夹、下夹、螺栓、螺母、弹簧垫圈)的具体安装位置我们以B型钢格板安装夹为例,我们可将所有型号的钢格板安全可靠地紧固在支承梁上,仅使用螺丝刀,在平台上面,一人可独立完成,操作快捷,安全。
Installation clamp parts include: (upper clamp, lower clamp, bolt, nut, spring washer) the specific installation position we take the B-type steel grille clamp as an example, we can all types of steel grille safely and reliably fastened on the support beam, using only screwdriver, on the platform, one person can complete independently, fast operation, safety .